loading

ACITEK, since 2005, specializes in water quality sensors, providing OEM/ODM service for pH, ORP, conductivity, DO, ion electrodes.

Do Transmitter by ACITEK 1
Do Transmitter by ACITEK 2
Do Transmitter by ACITEK 3
Do Transmitter by ACITEK 4
Do Transmitter by ACITEK 5
Do Transmitter by ACITEK 6
Do Transmitter by ACITEK 1
Do Transmitter by ACITEK 2
Do Transmitter by ACITEK 3
Do Transmitter by ACITEK 4
Do Transmitter by ACITEK 5
Do Transmitter by ACITEK 6

Do Transmitter by ACITEK

Inquiry
Send your inquiry

Product details of the Do Transmitter


Product Introduction

The design of Do Transmitter is original. Strict quality standards have been set during the inspection process to ensure high quality products. The scope of the market application of the product has been enlarged gradually due to its remarkably good characteristics.

G300 Product parameters

 

DO Measurement range
0.00~40.00 ppm
Resolution
0.01 ppm
Accuracy
±0.01 ppm
Temperature measurement range
-10.0~130.0 ℃
Resolution
0.1 ℃
Accuracy
±0.3 ℃
Temperature input type
NTC
Temperature compensation
automatic / manual
Signal output
Output type,two ways 4 ~ 20 mA (adjustable)
Current accuracy
±1%FS
Output load
<500 Ω
Data transmission
RS-485 output;MODBUS - RTU communication protocol
Switch control
Control mode-2 SPST relays
Load capacity
2.5A 230 VAC
Third circuit relay
functional relay (user can set cleaning or alarm)
Other parameters
Working power supply
85~260 VAC or 24 VDC (optional before order)
Working temperature
0~60°C
Working humidity
relative humidity < 90%
Levels of protection
IP65
Installation method
the dial installation
Physical dimension
108×108×132 mm(H*W*D)
Open hole size
92.5×92.5 mm(positive allowance )
Note
Simulanalog DO electrodes for MT and Hamilton

 

 

 

 

Product characteristics

●128*64 Dot array LCD display, Chinese and English can switch, IP65 protection level, all-weather stable operation;

●Simple menu design, simple and convenient operation, graphical prompt, beautiful and clear interface;

●The software digital filtering is adjustable, and the hardware anti-interference ability is enhanced, making the measurement more stable and adapted to the complex industrial environment;

●The global universal power supply is 85~260VAC, and can also be customized DC 18~24VDC

●RS-485 digital interface, MODBUS-RTU communication protocol, read and write two-way communication, can realize the remote complete control of the instrument

●Two measurement modes: DO or Temperature

050-004

ACOxyGold/G/120 Product parameters

 

Parameter

DO (Electrochemical)

Sensor Output Traditional

nA

a-length

120 mm

Electrical Connector

VP6

Measurement Principle

Electrochemical reduction of oxygen

Measuring Range

0.1 ppb to 40 ppm (DO) or 0.02 to 1000 mbar (pO₂)Additional specifications

Drift at Room Temperature

< 1 % per week

Oxygen Consumption

Ca. 100 ng/h in air at 25 °C

Temperature Sensor

NTC

Diameter

12 mm

Process Connection

PG13,5

Wetted Parts

Stainless Steel 1.4435;Silicone

Surface Quality of Steel

Ra < 0.4 µm (N5)

Electrode system

Silver platinum combination

Serial Number

Yes

Response Time t90%

< 60 s at 25 °C

Operating Temperature Range

0 to 60 °C

Pressure Range bar g

0 to 4 bar

Max. CO₂ Partial Pressure

0.01 bar

Required Flow

≥ 0.1 m/s

 

 

Product details

049-001
Simple menu design, simple and convenient operation
049-003
Three cable holes for easy storage of cables
049-004
IP65 protection level, all-weather stable operation

FAQS

1
What installation methods are supported by the instrument?
Panel installation.
2
What are the types of output signals?
The global universal power supply is 85~260VAC, and can also be customized DC 18~24VDC.
3
What components does this set include?
Including Controller, Mounting Hardware, Oxygen sensor, Cable, Flow-Chamber, Basic User Manual.
4
What is the response time of the instrument?
Response time within one minute.
5
How often does it take to calibrate to ensure accurate data?
Calibrate once every three months.


Company Advantage

• ACITEK's products are mainly exported to Europe, America, Asia and Africa and other countries and regions.
• The open and smooth traffic creates convenience for the transportation and timely supply of Water Quality Sensor,Water Quality Meter,Water Transmitter,Water Analyzer Accessory.
• Founded in our company has always put the quality of products and customer satisfaction in the first place. So, we can gain the favor of consumers.
• ACITEK runs an excellent, complete and effective sales and technical system. We strive to provide efficient services covering from pre-sales, in-sales, and after-sales, so as to meet customers' needs.
We have high production efficiency, and we look forward to the cooperation with you.

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
ACITEK, since 2005, specializes in water quality sensors, providing OEM/ODM for pH, ORP, conductivity, DO, ion electrodes.
Contact Us
Contact person: Jane Zhou
Tel: +86 17708471954
Add:

Lane 1505, Lianhang Road, Minhang District, Shanghai

Copyright © 2026 Shanghai Guizhen Instrument Equipment Co., Ltd.  | Sitemap | Privacy Policy
Customer service
detect