Place of Origin: Shanghai, china

purpose: Industry, laboratory, other

warranty period: one year

Support customization: OEM, ODM

Logo: ACITEK

model:ACPHER 112 SE

type: pH sensor

equipped with a rechargeable battery: No

Thread:PG 13.5

Sensor shaft:Glass

5.0
design customization

    oops...!

    no product data.

    Go to homepage


    Product Introduction


    Reliable online measurement of pH values – with ACITEK sensors;
    The online measurement and adjustment of pH values must be as accurate, fast and reliable as possible and provide good availability of the measured values, be it for the monitoring, control or regulation of chemical processes.
    Our pH sensors are manufactured to very strict quality controls (e.g. in accordance with RoHS guidelines). Routine steps are automated but critical steps are carried out manually under expert supervision. In this way we achieve the best reproducible quality and cost reduction.
    043-004
    043-006


    Product Features and Advantages

    -Precise and reliable pH measurement enables efficient processes and excellent process reliability
    -A long service life is achieved through the use of the best quality materials for the glass and diaphragms, a stable reference system and optimised production. This minimises both downtime and maintenance
    -With short storage times and fast delivery, your pH sensors can be up and running very quickly and you can make maximum use of their service life (all glass sensors start to age as soon as they leave production)
    -Wide range of special versions for fitting length, cable length and plugs for made-to-measure connection to your process
    -Unique label for OEM partners

    Product parameters

    Technical specification
    pH-range 0…14
    Temperature 32…176 °F (0…80 °C)
    Max. pressure 87 psi
    Min. conductivity 40 µS/cm
    Electrolyte Gel containing potassium chloride with KCI reservoir
    Diaphragm PTFE ring diaphragm
    Sensor shaft Glass
    Shaft diameter 0.47 inch
    Installation length 4.72 ±0.12 inch
    Fitting position Vertical up to +25°
    Thread PG 13.5
    Electrical Connection S8M plug-in head,5m cable rotatable with a ACITEK cable
    Enclosure rating IP 65
    Process integration Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube
    Controllers G300,G400,
    Typical applications Municipal and industrial waste water, cooling water, process water: containing moderate amounts of solids without high levels of chemical contamination.
    Resistance to Disinfectant, solids content (turbid types of water)
    Measuring principle, technology Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed

     

     

     

     

     

     

     

     

     

    Product details

    1 (31)
    Sensor shaft:Glass
    2 (31)
    S8M plug-in head,5m cable rotatable with a ACITEK cable
    3 (25)
    Thread:PG 13.5

    FAQS

    1
    Do you have any instrument options that can be paired with this electrode?
    We have instruments with models G300 and G400 to choose from for pairing with this electrode.
    2
    How long is the lifespan of the sensor?
    Sensor warranty for six months.
    3
    Can this electrode be customized with a matching cable?
    We can customize cable lines according to customer requirements.
    4
    What should be noted when using electrodes?
    When using electrodes, the insertion angle must be greater than 15 ° from the horizontal plane; The maximum flow rate is less than 0.8 meters per second, and the electrode is calibrated using international standard solution.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    ACITEK, since 2005, specializes in water quality sensors, providing OEM/ODM for pH, ORP, conductivity, DO, ion electrodes.
    Contact Us
    Contact person: Jane Zhou
    Tel: +86 17708471954
    Add:

    Lane 1505, Lianhang Road, Minhang District, Shanghai

    Copyright © 2025 Shanghai Guizhen Instrument Equipment Co., Ltd.  | Sitemap | Privacy Policy
    Customer service
    detect